Technical product characteristics H70/104AC - H70/105AC

SUPPLY VOLTAGE

MAXIMUM POWER CONSUMPTION
CONNECTABLE MOTORS
POWER SUPPLY MOTORS
MOTOR TYPES
MOTOR CONTROL TYPE
RATED POWER MOTOR
MAXIMUM POWER FLASHING LIGHT
MAXIMUM POWER COURTESY LIGHT
GATE OPEN LIGHT POWER
ELECTRIC LOCK POWER
OPERATING TEMPERATURE
DEGREE OF PROTECTION
PRODUCT DIMENSIONS
4

Description of connections and fuses

Figure 1 shows the connection diagram for the
power supply, motors and fuses.
The board has two quick type 5x20 mm fuses, F1 of
6,3A 250V (F6,3A) and F2 of 315mA 250V (F315mA).
Figures 2 and 3 show the connections of the inputs
and the outputs; below the description of the
individual terminal blocks:
1
L (Line), power supply input 230Vac 50Hz
2
N (Neutral), power supply input 230Vac 50Hz
3
Earth connection – mandatory to meet the
line safety and filtering requirements
4
AP, 230Vac motor output: opening
5
CM, 230Vac motor output: common
6
CH, 230Vac motor output: closing
Connect a capacitor using the value indicated
in the motor instructions.
7,8
COR, courtesy light (pure contact): maximum
voltage 230Vac, see technical features.
Alternatively you can connect an electric lock
if you set parameter
9,10 LAM, flashing (pure contact): maximum
voltage 230Vac, see technical features
11
24Vac, power supply for external devices (6W,
maximum current 250 mA, to be reduced to
200mA in the case of devices that do not have
an on-board rectifier bridge)
12
SC, gate open light (24Vac, 2W); alternatively,
you can connect the power supply for the
photocells transmitters (TX) to this terminal
bloc (provided that you set parameter
230Vac ± 10% 50Hz
1300W
1
230Vac
single-phase asynchronous
phase adjustment with triac
600W
40W 230Vac - 25W 24Vac/dc (pure contact)
100W 230Vac - 25W 24Vac/dc (pure contact)
2W (24Vac)
6W (24Vac)
-20°C ... +60°C
IP00
Dimension in mm. 98 x 141 x 40 Weight: 0,48 Kg
79 99
.
A8
the value
"photocell test" functionality
13
COM, common to low voltage inputs and
outputs
14
FT2, photocell 2 (N.C. contact)
15
FT1, photocell 1 (N.C. contact)
16
COS2, safety edge 2 (N.C. contact or 8.2kOhm)
17
COS1, safety edge 1 (N.C. contact or 8.2kOhm)
18
ST, STOP command (contact N.C.)
19
PP, step-by-step command input
20
Receiving antenna cable braiding
21
Antenna cable pole for plug-in radio receiver
(if you are using an external antenna, connect
it with RG58 cable)
22
ORO, clock command input
23
PED, pedestrian opening command input
(N.O. contact): factory set it opens the leaf to
30% of the limit switch
24
CH, closing command input (contact N.O.)
25
AP, opening command input (contact N.O.)
26
COM, common to low voltage inputs and outputs
27,28 COM, common to low voltage inputs and outputs
Encoder, limit switches and unlock switch terminal
blocks, on the top left of the board (figure 4), will
vary depending on the board model (H70/104AC o
H70/105AC).
H70/104AC has 3 white connectors, it only fits
ROGER automations where the control unit is built
into the motor and is pre-wired. The connectors