Changing a parameter

Using the UP and DOWN buttons to view the
parameter to be changed, then with the + and -
buttons change its value (the number on the right
starts flashing). While holding down a button, after
one second quick sliding is activated, allowing you
to change the parameter quicker. To save the value
set on the display, wait a 4 seconds, or move to
another parameter with the UP and DOWN buttons:
the whole display will flash quickly indicating that
the parameter has been saved.
NOTE: Changing the numerical value of the
parameters with the + and - buttons is only possible
with the engine stopped, while consultation of the
parameters is always possible.
The sequence of parameters in the mode simplified
STANDARD
PARAMETER
AND VALUE
Position of the motor
0- 00
with respect to the gap
1- 00
Automatic reclosing
2- 30
Pause time
3- 00
Emergency blackout
4- 00
"generator" mode
5- 00
Pre-flashing
6- 00
Step-by-step mode
7- 00
Flashing activation
8- 00
Enabling limit switch
9- 05
Normal operating torque
A- 00
Torque during slowdown
b- 01
Select encoder
24
VALUE ON
FUNCTION
DISPLAY
01 - 15 number of attempts to reclose (interrupted by
00 - 90 seconds of pause
92 - 99 2 minutes...9 minutes of pause
01 - 10 pre-flashing seconds
01 - 08 1 minimum torque ... 8 maximum torque
01 - 08 1 minimum torque ... 8 maximum torque
is shown in the table below.
ATTENTION! Some parameters (
are particularly critics, and change them with the
system already started,may cause malfunction; to
give effect to the change in their value you have to
disconnect the power supply and then restart the
system and re-programming the stroke.
6.2.2
Restoring standard factory
parameters
N.B.: this procedure is only possible if you have not
entered the password to protect your data.
Turn off the control unit, simultaneously press and
hold the UP and DOWN buttons then turn on again
and keep up pressing the buttons: after 4 seconds
the display will show the writing
which indicates that the values have been restored.
motor on the LEFT with respect to the gap looking from inside
00
motor on the RIGHT with respect to the gap looking from inside
01
deactivated
00
photocell) before finally staying opened
always tries to reclose
99
deactivates the reclosing when power returns
00
enables the reclosing when power returns
01
Deactivated
00
enables a digital filtering for additional power from
01
generators
deactivated
00
5 seconds of pre-flashing only when closing
99
open stop close stop open stop close ...
00
condominium, refreshes the pause time
01
ccondominium, closes from completely open
02
open close open close
03
open close stop open
04
fixed
00
one flash per second
01
normal flash when opening, fast when closing
02
no limit switch connected
00
limit switch on opening and closing connected
01
only limit switch on opening connected
02
Disabled
00
optical encoder
01
magnetic encoder
02
0-
rE S-
DESCRIPTION
8-
b-
,
e
)
flashing,