6.2.3

Simplified/extended parameters

The
control
unit
configuration: extended or simplified.
In extended mode the installer can change a lot
of parameters, but you need a more in-depth
knowledge of the product.
Simplified mode has been designed for easy of
installation, only a few parameters can be changed.
It is the recommended mode for an installer who is
not very familiar with the product and who does not
need special configurations.
WARNING!
The product leaves the factory set in simplified mode.
If you want to go to extended mode hold the UP and
DOWN buttons both for 4 seconds, after this time
the first of the parameters of the extended version
will be displayed on the display, which is highlighted:
• by the presence of two decimal points on the
first two left digits (representing the parameter
number)
A
• of the letter
in parameters less than 10, to
distinguish them from those of the simplified
version (which are different)
N.B.: The operation can be performed several times,
switching from one mode to another at will.
The table in paragraph 11 contains the parameters
for extended mode
N.B.: the sequence of parameters for simplified
mode is not the same as that of extended mode,
therefore always refer to the instructions or the
label on the inside of the cover.
6.3

Standby mode

After 30 minutes of inactivity, the control unit enters
standby mode, and the display only indicates a
flashing dot. The activation of standby automatically
provides
two
modes
SIMPLIFIED MODE
hold the buttons for 4 s
EXTENDED MODE
resets the simplified parameters mode.
The mode remains at rest on the display, but the
control unit is always ready to perform commands;
to turn the display back on you have to press one of
of
the buttons UP,DOWN,+,-.
6.4

TEST mode

This is activated by pressing the TEST button, only if
the motors are stationary; otherwise, the TEST button
performs a STOP command and only the subsequent
operation of the button enables test mode.
The display is as follows:
Name of the active input
(displayed for 5 seconds)
AP
CH
PP
PE
Or
Allows you to visually inspect the activation of the
commands and the safety protections: upon each
of their activations, the control unit briefly activates
the flashing and the Gate Open Light (terminal block
no. 12, SC)
The display indicates:
• the command activated, in fixed letters (on the
left-hand side, for a period of 5 seconds)
• in a flashing number, the safety protection
terminal block in a state of alarm (right part,
displayed as long as the safety protection is in a
state of alarm). They are instead represented by
letters unlocking it (given that it does not have a
terminal block number) and limit switches (given
that inputs FC1 and FC2 change their function in
relation to the setting of parameter
If no safety protection is in a state of alarm
displayed, therefore the control unit is enabled to
perform the commands; the only exception is when
a limit switch is activated, which appears but does
not constitute a barrier to issuing a command.
After 10 seconds of inactivity it will return to
safety protection terminal
block number in a state of
alarm (flashing, displayed
until the safety protection
goes back to resting)
Sb =
highest
unlock
priority
18 = ST
17 = COS1
16 = COS2
15 = FT1
14 = FT2
opening
FA =
limitswitch
lowest
priority
FC =
closing
limitswitch
71
).
00
, is