1. Unpacking Instructions
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Tools Needed for Assembly
One Phillips Head Screwdriver
One Wire Stripper
Materials
Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would be a
3-conductor (2-wire with ground) of following size:
Installed Wire Length
Up to 50 ft.
50-100 ft.
IMPORTANT: Your ceiling fan will not function
properly, and may be damaged, if used with any wall
dimmer switch or control other than the Emerson
Electric Fan/Light Remote Control supplied with the
fan.
Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of
withstanding a load of at least 50 pounds.
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable for
Fan Support of 22.7 kg. (50 lbs.) or less", and use screws
supplied with outlet box. Most outlet boxes commonly
used for support of light fixtures are not acceptable for
fan support and may need to be replaced. Consult a
qualified electrician if in doubt.
Install, Operate and Maintain Your Ceiling Fan
One Stepladder
One Wire Cutter
Wire Size A.W.G.
14
12

2. Electrical Requirements

(Continued)
Your Emerson ceiling fan comes supplied with a Fan/Light
Remote Control which consists of a receiver mounted
inside the ceiling cover of the fan motor housing. This
system allows you to regulate your ceiling fan speed and
light ON/OFF.
!
Before assembling your ceiling fan, refer to section on
proper method of wiring your fan (page 9). If you feel you
do not have enough wiring knowledge or experience,
have your fan installed by a licensed electrician.
If your fan is to replace an existing ceiling light fixture, turn
electricity off at the main fuse box at this time and remove
the existing light fixture.
!
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse box before wiring. All wiring must be in
accordance with National and Local codes and the ceiling
fan must be properly grounded as a precaution against
possible electrical shock.
!
To avoid fire or shock, follow all wiring instructions
carefully.
Any electrical work not described in these
instructions should be done or approved by a licensed
electrician.
Please
call
Emerson
1-800-654-3545 if you have any questions about
installation and operation of this ceiling fan.
4
WARNING
WARNING
WARNING
technical
support
U.L. Model No.: CF145L & CF153L