Bosch MIC‑ALM‑WAS‑24 Manual Del Usuario página 36

Ocultar thumbs Ver también para MIC‑ALM‑WAS‑24:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

36
en | Installation
Pin
1
2
3
4
5
6
7
8
9
10
11
12
8. Connect the washer pump drive, if desired.
2019-12 | 3.0 | F.01U.382.777
according to the table below.
Note 1: Pins are numbered from right to left on terminal
block P101.
Note 2: Any of the GND terminals can be used with any
alarm input/output.
Description / Function
Alarm Input 3
Alarm Input 4
Alarm Input 5
Alarm Input 6
Ground
Alarm Output 1
Alarm Output 2
Alarm Output 3
Ground
Tamper Alarm Input 1
Tamper Alarm Input 2
Ground
Check that the connections are secure.
If tamper alarm inputs are used, attach a 2.2 K ohm end-of-
line termination near the alarm contact.
Prepare the cable as needed.
Select the cable gland in the most suitable location based
on installation conditions. Item 12 is recommended.
Feed the cable through the cable gland into the enclosure.
Make the connections to terminal block P100 (item 10)
according to the table below.
MIC Alarm-Washer Box
LED
AI1
AI2
AI3
AI4
AO1
AO2
AO3
Bosch Security Systems