MIC Alarm-Washer Box
Pin
1
2
–
9. Verify power to the device.
–
–
The table below identifies the behavior of the LEDs on the PCBA
when the device is working as expected.
Red LED
Green LEDs
Yellow LED
10. Complete installation.
–
–
–
Bosch Security Systems
Description / Function
Relay Normally Open
Relay Common
Check that the connections are secure.
Apply power to the device.
If desired, test the washer by pushing the red button
labeled "PUMP ON" on the PCBA (item 11).
The LED labeled "WASHER" on the PCBA (item 13)
illuminates in response to telemetry commands to turn on
the washer. Note that the software in the camera prevents
the washer from running more than 10 seconds
continuously to prevent emptying the washer bottle.
LED
Indicator
ON
Blinking
Blinking
Re-attach the enclosure lid.
Tighten the four (4) lid screws to 1.5 N m (9 - 13 in. lb) to
ensure that the enclosure is watertight.
If desired, slide the screw caps over the lid screws to
protect the enclosure from tampering.
Installation | en
Description
Power ON
Alarms active
RS-485 communications
active
2019-12 | 3.0 | F.01U.382.777
37