Components
This stove is equipped with the following control and safety components:
•
3 bar safety valve;
•
Booster pump control thermostat (integrated in the functions of the electronic board);
•
Acoustic alarm activation thermostat (integrated in the functions of the electronic board);
•
Temperature indicator (integrated in the functions of the electronic board, with display);
•
Pressure indicator (integrated in the functions of the electronic board, with display);
•
Acoustic alarm (integrated in the functions of the electronic board);
•
Automatic regulation thermal switch (integrated in the functions of the electronic board);
•
Automatic blocking thermal switch (manual reset thermostat);
•
Circulation system;
•
Expansion system (Expansion vessel).
Local laws and regulations (for example the UNI 10412-2 standard valid in Italy) could provide for other safety components. In this
case they must be mounted in the system.
The construction of a heating system with the relative installation of the boiler must comply with all national and local regulations in
force in the place where the system is carried out.
Stove-system connection
3/4'' Flow
3/4'' Return
Ø 15
Safety drain
Ø 15 Drain
Connect the stove to the hydraulic system so as not to constrain it excessively and to allow it to move slightly.
Before connecting the thermo-stove, it is strongly recommended that the system be thoroughly washed in order to eliminate
residues and deposits.
Use and maintenance manual RBH 150 V - RBH 200 V
EN
Rev.2 15/07/2021
Pag.37
Jolly valve
(automatic vent
valve)
Pump