7-2-2
Checking the Plunger for Wear
1.
Remove 4off Torx screws (M5x12) and remove the cover (M)
Torx screw (M5 x 12)
2.
Depress the Pedal by hand and visually check that the Plunger operates the Micro
Switch.
Foot plate
3.
If the Plunger is worn and does not operate the Micro Switch, replace the Plunger.
4.
Reassemble in reverse.
Cover (M)
Microswitch
Torx screw (M5 x 12)
pedal
released
Whizz nut
Pedal
pressed
Plunger
73