Replacing The Gun Harness - NAMCO TIME CRISIS 4 DX Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12

7-20 Replacing the Gun Harness

1.
Remove the Gun Assy
2.
Remove the 2off button head screws (M4x10) and detach the Connector Cover B.
3.
Remove the Gun Slides
4.
Remove the cap screw (M3x5) and remove the Earth terminal and tooth washer (M3).
5.
Disconnect the connectors and remove the two Faston terminals from the microswitch.
6.
Remove the button head screw (M3x8) that attaches the Gun Harness to the Gun
Body (L), and replace the Gun Harness.
Microswitch
Connect the blue wire to
the N.O. terminal.
Faston terminals
7.
Reassemble in reverse order.
After replacing the Gun Harness, go to Test Mode to check operation.
(see 6-2-3-3 page 61)
Be sure to initialize the Guns.
(see 6-2-3-2 page 58)
(See 7-14 page
89)
(See 7-15 page 90)
and the Gun Body.
Connect the black wire to the COM terminal.
(See 7-16 page 91)