25 9.2 Replacement Easy Aludata Calliper; Width Potentiometer Positioning Procedure - Bosch WBE 4140 Instructions De Réparation

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

en
40 | WBE 4140 | Replacement interventions
10. Screw the nut until you cannot turn it manually;
i
Manually: lock the nut making a half turn with the
key;
i
With a dynamometric key, apply a 4 n/m strength;
11. Keep the Allen key and fix the locking nut (fig.14);
Fig. 14:
12. Mount again the shaft inside the machine;
13. Reconnect the engine.
i
In order to check that the reparation has been
successful, check the tensions again and go on
making a new calibration of the machine.
9.2
Replacement Easy Aludata calliper
1. Remove the weights protection;
2. Disconnect the action-centre;
3. Loosen the fixing screw of the feeler (fig.15, pos.1);
Fig. 15:
4. Extract the entire Easy Aludata calliper unit from the
machine;
5. Replace the calliper unit
6. Reassemble it following the same disassembling
procedure.
|
1 695 655 779
2010-11-9
9.�
1. Remove the left side protection without
2. start the balancing machine;
3. access the test menu;
4. keeping the 4 value displayed on the board, release
Fig. 16:
5. keeping the calliper in stand-by, turn the
Fig. 17:
1
6. Lock the fixing screw ensuring that the upper
7. check the correct functioning during the run;
8. close the machine;
9. proceed with calibration of the callipers.
!
Width potentiometer positioning
procedure
disconnecting the board;
the screw on the ring nut (fig.16);
potentiometer using nose pliers (fig.17) to the value
of 1000 ± 50;
surface of the pinion and of the rack are complanar;
The above notes are to be used for the correct
repairing; in case of replacing the entire calliper unit,
proceed only with the calibration.
Robert Bosch GmbH

Publicidad

Tabla de contenido
loading