Before beginning installation procedures,
these installation and operating instruc-
tions should be studied carefully. The
installation and operation should also be in
accordance with local regulations and
accepted codes of good practice.

1. General description

With float
switch
Fig. 1
1. Discharge port Rp 1¼.
2. Handle.
3. Clamp.
4. Suction strainer.
5. Outer casing.
6. Float switch.
7. Vertical level switch.

1.1 Applications

The Grundfos Unilift KP 150, KP 250 and KP 350
pumps are single-stage submersible pumps
designed for pumping grey wastewater.
6
Pumps with float switch:
The pump is capable of pumping water which con-
Page
tains a limited quantity of solids up to 10 mm in diam-
6
eter without being blocked or damaged.
6
The pump is suitable for automatic as well as manual
6
operation and can be installed in a permanent instal-
7
lation or used as a portable pump.
7
The pump is suitable for:
7
• pumping of wastewater from washing machines,
7
7
8
• drainage of cellars or buildings prone to flooding.
8
9
• pumping in draining wells.
9
• pumping in wells for surface water with inlets from
9
10
• emptying swimming pools, ponds or fountains.
11
Pumps with vertical level switch:
11
The pump must only be used for the pumping of
clean ground water and drain water.
General:
The pump is not suitable for pumping:
• liquids containing long fibres,
• inflammable liquids (oil, petrol, etc.),
With vertical
• aggressive liquids.
level switch
Note: The pump contains approx. 70 ml of non-
poisonous motor liquid that may pollute the pumped
liquid if the pump should leak.

1.2 Operating conditions

Liquid temperature:
Minimum 0°C. The maximum liquid temperature
depends on the rated voltage of the pump, see the
table below.
* Voltage variant for Unilift KP 350
baths, sinks, etc. from low-lying parts of buildings
up to sewer level.
roof gutters, pits, tunnels, etc.
The pump must not be used in or at swim-
ming pools, garden ponds, etc. when there
are persons in the water.
Voltage
1 x 100 V, 50 Hz
1 x 110 V, 50 Hz
1 x 100-110 V, 50 Hz*
1 x 220-230 V, 50 Hz
1 x 220-240 V, 50 Hz*
1 x 230-240 V, 50 Hz
1 x 100 V, 60 Hz
1 x 115 V, 60 Hz
1 x 220 V, 60 Hz
3 x 200 V, 50 Hz
3 x 380-400 V, 50 Hz*
3 x 380-415 V, 50 Hz
3 x 200 V, 60 Hz
At intervals of at least 30 minutes, the pump is
allowed, however, to run at maximum +70°C for
periods not exceeding 2 minutes.
Maximum
liquid temperature
+35°C
+40°C
+40°C
+50°C
+50°C
+50°C
+35°C
+50°C (+45°C KP 350)
+40°C
+35°C
+50°C
+50°C
+35°C