Pump Location; Adjustment Of Float Switch - Grundfos Unilift KP 150 Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para Unilift KP 150:
Tabla de contenido

Publicidad

When the pump is installed in a permanent installa-
tion with float switch/vertical level switch, a non-
return valve must be fitted in the discharge pipe/
hose. If the pump is installed in a well and with a
minimum free cable length according to figure 9, the
minimum dimensions of the well should be as shown
in figure 4 to ensure free movability of the float
switch. Figure 5 shows a pump with a vertical level
switch.
Furthermore, the well should be sized according to
the relation between the water flow to the well and
the pump capacity.
With float switch
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
ø 350 mm
ø 350 mm
Fig. 4
With vertical level switch
ø 250 mm
ø 250 mm
Fig. 5

3.2 Pump location

Pumps without or with float switch can be used in
vertical position with the discharge port uppermost or
in horizontal or tilted position with the discharge port
as the highest point of the pump, see fig. 6.
Note: Pumps with vertical level switch must be used
in vertical position.
8
400 mm
400 mm
400 mm
Fig. 6
When the pipe/hose has been connected, the pump
is ready for use.
Note: Do not lift the pump by means of the electric
cable. Lift the pump by means of the discharge pipe/
hose or a wire secured to the handle of the pump.
Before positioning the pump, make sure that the suc-
tion strainer will not be blocked or partly blocked by
silt, mud or similar materials.
This can be avoided by positioning the pump on
bricks, an iron plate, etc., see fig. 7.
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
Fig. 7

3.3 Adjustment of float switch

The difference in level between start and stop can be
adjusted by changing the free cable length between
the handle of the pump and the float switch.
Large difference in level: long free cable. This
cable length must not exceed 150 mm, see fig. 8.
Max
Max.
150 mm
150mm
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • • • • • •
• • • • • • • • • •
• • • • • • • • • •
• • • • • • • • • •
• • • • • • • • • • •
• • • • • • • • • •
• • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • • • •
• • • • • • • • • • • •
•• • • • • • • • • • • • •
Fig. 8
* For Unilift KP 350 the distance between the bot-
tom of the suction strainer and the lowest level of
the float is 110 mm.
Start
Start
225 mm
225mm
Stop
Stop
100 mm (110 mm*)
100mm