Basic Configuration

1. Determine the necessary conversion operations to
convert from the factory-supplied configuration
to the desired configuration.
2. Perform the conversions required so the machine
is properly configured for the desired country and
gas (refer to Specific Conversion Procedures
section):
How to Convert Gas Valve from Regulated to
G
Unregulated
NOTE: Conversion from regulated to unregulated
is only needed when regulated tumblers were
ordered, but unregulated tumblers were needed.
How to Change Injector (Orifice) Size
G
How to Adjust Gas Valve Governor/Regulator
G
How to Change Regulator Spring DE/AT
G
Only.
3. If applicable, peel off the appropriate country
sticker from Part No. 503382 or M413919
(included with machine) and apply it to the serial
plate over the existing country information. Refer
to Figure 9.
4. If applicable, peel off the appropriate conversion
sticker from Part No. M413800 or M413919
(included with machine) and apply it to the serial
plate over the "ADJUSTED FOR ______ GAS:
______" information. Refer to Figure 9.
5. Commission tumbler for use.
WARNING
When converting the tumbler to a
different gas or pressure, first verify that
the supply inlet pressure is equipped with
a pressure regulator (located ahead of the
tumbler) that will maintain the gas supply
at the inlet pressure specified.
28
W430
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
SPECIFIED
LOCAL INLET
PRESSURE
2
1
1
Gas Shut-Off Valve (Ahead of pressure tap)
2
Pressure Tap
3
Gas Shut-Off Valve (Shown in closed position)
Figure 6
3
T103K
70223701

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido