Electrical Requirements
For 30 Pound Stacked Gas and Steam Models
(For Total Machine):
Serial Plate
Voltage
120V/60Hz/1ph
208-240V/60Hz/1ph
100V/60Hz/1ph
200-220V/60Hz/1ph
100V/50Hz/1ph
200V/50Hz/1ph
230-240V/50Hz/1ph
200-208V/60Hz/3ph
240V/60Hz/3ph
200V/50Hz/3ph
230-240V/50Hz/3ph
380V/50Hz/3ph
400-415V/50Hz/3ph
460-480V/60Hz/3ph
58
Terminal Block
Current
Connections
(Amps)
Required
L1, Neutral,
and ground
L1, L2, Neutral,
and ground
L1, Neutral,
and ground
L1, Neutral,
and ground
L1, Neutral,
and ground
L1, Neutral,
and ground
L1, Neutral,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
L1, L2, L3,
and ground
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Recommended
Fuse or
Breaker Rating
(Amps)
15.0
20
8.0
10
22.0
30
11.6
15
24.2
40
15.0
20
15.0
20
6.3
10
6.3
10
5.8
10
7.0
10
3.0
10
3.2
10
3.3
10
Table 18
Recommended
Breaker
Minimum
Poles
Conductor Size
[AWG (mm
1
12 (3.53)
2
14 (2.27)
1
10 (5.52)
1
14 (2.27)
1
8 (8.81)
1
12 (3.53)
1
12 (3.53)
3
14 (2.27)
3
14 (2.27)
3
14 (2.27)
3
14 (2.27)
3
14 (2.27)
3
14 (2.27)
3
14 (2.27)
2
)]
70223701