Failure Display And Inspection - Brandt BPI6390B Manual De Instrucciones

Ocultar thumbs Ver también para BPI6390B:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Pans do not become
hot and appears in the
display.
The induction hob or a
cooking zone has
turned itself off
unexpectedly, a tone
sounds and an error
code is displayed
(typically alternating
with one or two digits
in the cooking timer
display).

8. Failure Display and Inspection

The induction hob is equipped with a self diagnostic function. With this test the technician is able to
check the function of several components without disassembling or dismounting the hob from the
working surface.
Troubleshooting
1) Failure code occur during customer using & Solution;
Failure code
Supply voltage is above the rated
E1
voltage.
Supply voltage is below the rated
E2
voltage.
High temperature of ceramic plate
E3
sensor .(1#)
High temperature of ceramic plate
E4
sensor .(2#)
High temperature of IGBT .(1#)
E5
High temperature of IGBT.(2#)
E6
Ceramic plate temperature sensor
F3/F6
failure- -short circuit. (F3 for 1#,F6
for2#)
F4/F7
Ceramic plate temperature sensor
The induction hob cannot
detect the pan because it is not
suitable for induction cooking.
The induction hob cannot detect
the pan because it is too small
for the cooking zone or not
properly centred on it.
Technical fault.
Problem
Auto-Recovery
No Auto-Recovery
Use cookware suitable for induction
cooking. See section 'Choosing the
right cookware'.
Centre the pan and make sure that its
base matches the size of the cooking
zone.
Please note down the error
letters and numbers, switch
the power to the induction hob
off at the wall, and contact a
qualified technician.
Please inspect whether power supply is
normal.
Power on after the power supply is
normal.
Wait for the temperature of ceramic
plate return to normal.
Touch "ON/OFF" button to restart unit.
Wait for the temperature of IGBT return
to normal.
Touch "ON/OFF" button to restart unit.
Check whether the fan runs smoothly;
if not , replace the fan.
Check the connection or replace the
ceramic plate temperature sensor.
EN-22
Solution

Publicidad

Tabla de contenido
loading

Tabla de contenido