1.
Turn off water supply and flush the toilet.
2. Remove the tank lid and place it upside
down on a clean surface. Remove the remain-
ing water from tank with a sponge.
3. Pull the clip on top of trip lever gear box as
shown. (ill. 1)
4. Pull gear box away. (ill. 2)
5. Rotate flush tower until arrow aligns with
overflow tube and then pull up to remove.
(ill. 3)
6. Remove the grey rubber seal gasket and
rinse under running water to clean. (ill. 4)
7.
Place the gasket back on the flush tower.
8. Align and place the flush tower into housing
and rotate to lock into place.
9.
Replace the trip lever gear box and push
down on lever to lock it in place.
10. Carefully install the tank lid back on the tank.
11. Flush the toilet several times making sure the
trip lever operates normally.
12. Check the water level in the tank and inspect
for signs of any leakage.