Thermador PH Serie Instrucciones De Uso página 3

Ocultar thumbs Ver también para PH Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Parts Included with your Hood
Hood Canopy
12-Volt halogen bulbs, installed
Care & Use /Installation Instructions
Registration Card
Filters (2, 3, or 4 depending on model and size)
Metal Transition with Back draft damper installed
Fasteners
Remote Blower ("pigtail") Adaptor
Wooden Strip for Hood Support
Wire Nuts
CONSIDERATIONS BEFORE INSTALLING HOOD
1. For the most efficient air flow exhaust, use a
straight run or as few elbows as possible.
CAUTION:
Vent unit to outside of building, only.
2. Do not use flex ducting.
3. COLD WEATHER installations should have an
additional backdraft damper installed to
minimize backward cold air flow and a
nonmetallic thermal break to minimize
conduction of outside temperatures as part of
the ductwork. The damper should be on the cold
air side of the thermal break. The break should
be as close as possible to where the ducting
enters the heated portion of the house.
4. Hood installation height above cooktop is the
users preference. The lower the hood above the
cooktop, the more efficient the capturing of
cooking odors, grease, and smoke. This hood
has been approved for installations as low as 24
inches* above the cooktop. The lower height
Parts Not Included with your Hood
Duct Tape
1/2" Conduit
2 175W PAR-38 Heat Lamps or
2 250W PAR-40 Heat Lamps
Ventilator- The hood can be installed with
ventilator models VTN1000Q, VTR600R,
VTR1000Q, and VTR1400Q
Optional duct cover, 6" DC**US or 12" DCT**US
height (available for purchase seperately)
** = width of hood
Optional Remote Control (available for purchase
separately)
may be inconvenient for tall people and large
cooking vessels. Consequently, Thermador
recommends the hood be installed 30-to-36
inches above the countertop.
*
For indoor grill installations, Thermador
recommends a minimum of 30" clearance and
remote blowers only (VTR1000Q or VTR 1400Q)
5. Remote blowers require a five wire installation.
6. Make-Up Air: Local building codes may require
the use of make-up air systems when using
ducted ventilation systems greater than specified
CFM of air movement. The specified CFM varies
from locale to locale. Consult your HVAC
professional for specific requirements in your
area.
7. Refer to Remote Control Installation Instructions
if applicable.
Page 3

Publicidad

Tabla de contenido
loading

Tabla de contenido