Assembly And Installation Of The Duct Covers - Thermador PH Serie Instrucciones De Uso

Ocultar thumbs Ver también para PH Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12. Before hanging hood, install
transition per Fig. 6. Fasten
transition with 2 screws (#8 x
3/8 sheet metal, supplied)
and tape per code. Note:
screws must not hinder
damper operation.
13. Rest the hood on the screws
in the wood bracket. Use the
keyholes labeled "I" in Figure
8. Make sure the wood
bracket fits into the recess
on the back of the hood.
14. Remove knockouts.
15. Tighten the screws in
keyholes. Check hood for
level and adjust if necessary.
16. From inside the hood drive
screws (#8 x 5/8") through
holes in hood into wooden
bracket. See holes labeled J
in Figure 8.
17. Connect additional ducting.

Assembly and Installation of the Duct Covers

Optional duct covers shown in
Figure 9 may be used to fill the
space between the hood and
ceiling in wall mount installations.
6" and 12" high duct covers are
available and may be ordered
separately.
1. If multiple duct covers are
used, connect the pieces
together using sheetmetal
screws provided with duct
covers.
2. Attach the duct cover(s) to
the hood using sheetmetal
screws as shown in Figure 9.
3. From inside of hood, insert
screws supplied (#8 x 5/8")
through holes L, one on each
side and four along the front,
into bottom of the cabinet.
I
Figure 8
Installation Note: If wall studs are within 8" of the center line, cut stud
at an angle to avoid any interference.
Figure 9
Page 7
J
L
L
I
#8 x 3/8"
Screw
(numbers
depend on
hood size)
L

Publicidad

Tabla de contenido
loading