7. CONNECTION EXAMPLES

7.1 No safety sensor
DIP3=ON
BL
41
8
6
4
3
1
0
8. START-UP
• Connect the accessories;
• Make a jumper on the safety contacts 41-8 and 41-6 on the control panel if not used;
• Reconnect the mains power supply to the automation;
• Enable the trimmer/dip switches adjustment (See paragraph 5.3);
• Select dips 1, 2, 3 and the trimmer TC based on the desired operation (See paragraph 5.3);
• Select dip "weight " 1, 2, 3 based on the wing weight if you want to use the automation with LOW ENERGY performance (see paragraph 6).
WARNING: the control panel performs an automatic RESET on each start and the first opening or closing manoeuvre is performed at low speed
allowing the automatic self-learning of the stop positions (acquisition).
• Check that the door is operating correctly with a further opening command.
• Check the operation of the connected accessories.
• If the automation encounters an obstacle during closure, it is detected and the automation opens again. If the automation encounters an obstacle
during opening, it is detected and the automation stops. If the obstacle is detected three times consecutively, it is considered as the new stop until
it is removed.
• The automation is equipped with the Push&Go/Pull&Close function. The motorised opening or closing operation is activated when the door is pushed.
If the automation is not powered, it is possible to slide the doors manually but only by moving them slowly.

9. ROUTINE MAINTENANCE PLAN

Perform the following operations and checks every 6 months, according to the intensity of use of the automation.
Without 230 V~ power:
• Clean the moving parts (the carriage guides).
• Check the belt tension.
• Clean the opening and closing sensors (if present).
• Check the stability of the automatic system and make sure that all screws are correctly tightened.
• Check the alignment of the door wing and the stop position.
Turn on the 230 V~ power:
• Check the stability of the door, and make sure it moves smoothly.
• Check that all control functions are operating correctly.
• Make sure the opening and closing sensors are working correctly (if present).
• Make sure the installation complies with the current regulations and the essential requisites laid down by the relevant authorities.
i
NOTE: for spare parts, see the spares price list.
Only use original spare parts for repairing or replacing products.
i
The installer must supply all information concerning the automatic, manual and emergency operation of the motorised automation or gate,
and must provide the user with the operating instructions.
The installer must prepare and keep a maintenance record showing all the routine and extraordinary maintenance work carried out.