In 24V mode, the green
and orange charge
indicators blink
abnormally.
After having pressed the
test key, no light
indicators are on.
2 leds blink intermittently.

Advice and warnings

• Explosive gas, avoid flames and sparks. While charging, the battery must be in a ventilated
area.
• Protect the machine against the rain and humidity.
• The machine must be installed so that the mains plug is accessible.
• The product must be plugged to a base with a 230V plug with earth.
• Check regularly the Energy Station, specially the power cord, the plug and the case, to
detect any damage. If the charger is damaged, it must not be used before reparation.
• If the electricity supply cable is damaged, it must be replaced by the manufacturer, its after
sales service, or a person with the same qualifications to avoid any dangers.
• Charger Mode : the battery terminal which is not connected to the frame must be
connected first. The other connection must be done on the frame far from the battery and
from the fuel system.
Energy Station
The fuse melt :
Problem with the
power supply
No batteries
Batteries polarities
reversal
Problem with the
power supply
To charge a 24V
external battery, the
Energy Station needs
its 2 internal batteries
to operate.
The machine is
plugged on the mains
and the charging
switch is on.
There is no battery.
The battery voltage is
to low.
The test updates every
0.5 seconds. The
battery voltage is on
the rocking threshold.
Replace the fuse : Check the
power supply.
The charger does not detect
the battery or the battery is
damaged
beyond
(voltage >0,5V).
Connect the red cable to the
(+) battery terminal and the
black cable to the (-) terminal
Check the power supply.
Place
the
missing
batterie(s).
Switch off the machine.
(charging switch on 0) or
disconnect the charger from
the mains 230V. Press again
the test key.
Check the internal battery
connections (fastening
collars...)
In this mode, the charger is
supplied through the battery
to test. If the battery voltage
is to low (<6V), no led will
switch on.
While reading, take the most
unfavorable case.
repair
internal
14/40