ANOMALIES
The Vehicle does not
start
Intense sparks when
connecting the clamps to
the vehicle battery.
The internal batteries are
charged, the starting
voltage choice is right,
but the vehicle does not
start.
The red light blinks (after
24h of charge)
The green and orange
lights blink turn by turn
while charging.
The orange light blinks
for more than 3h and
does not change to
green.
Energy Station
CAUSES
The internal batteries
are discharged.
Several starting were
attempted without
break.
Voltage error
Voltage error
Polarity reversal.
Vehicle problem
(rectifier, starter, glow
plugs...)
The battery does not
charge or its voltage
does not increase
enough.
Charger thermal
protection.
The battery is sulfated
or highly discharged.
REMEDIES
Check the internal batteries
condition by pressing the test
keys.
Charge if necessary.
Wait for 3 minutes between 2
starting attempts.
A starting must not last more
than 7 seconds.
Check the starting voltage
selected matches the vehicle
battery voltage.
Check the connections and
that
the
starting
matches the selected voltage.
Connect the red cable to the
(+) battery terminal and the
black cable to the (-) terminal.
Take
contact
professional.
Check the collars are well
tightened on the battery
terminals. Clean the terminals
and restart the charge. If the
red light blinks again, the
batteries are damaged.
Wait for several minutes (5 to
10 minutes) to cool the
machine. The charge will
automatically restart as soon
as the temperature will have
decreased enough.
The
charger
detects
presence of a sulfated or
highly discharged battery. It
will attempt to restore it with a
24h specific charge.
voltage
with
a
the