Kohler K-7514 Guía Del Usario página 12

Ocultar thumbs Ver también para K-7514:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Symptoms
3.
Low flow.
1244026-5-A
Probable Causes
Recommended Action
H. Bleed hole in the
H. Remove the spout
diaphragm is
body. Clean or replace
plugged or debris
the diaphragm.
exists on the seal.
I. Wires are pinched
I. Check the wires for
or damaged.
damage. Verify the
wires are tucked inside
the spout. Replace the
assembly with damaged
wires if needed.
J. There is a loose
J. Check the solenoid
connection.
and sensor connections.
Confirm the arrows are
aligned and connections
are secure.
K. There is water
K. Determine the cause
leaking internally.
of the leak. Check for
corrosion on
connections. Inspect the
valve O-ring for
damage. Replace if
needed. Clean the
terminals. Replace
damaged parts.
L. Solenoid is not
L. Install a new
working.
solenoid service kit.
A. Filter is plugged.
A. Clean or replace the
filters.
B. Supply pressure is
B. Check incoming
low.
water pressure. Pressure
should be at least 20 psi
(137 kPa).
C. Aerator is
C. Remove the aerator
plugged.
and clean it. For
calcium/mineral
deposits, soak the
aerator plastic insert in
a 50:50 mixture of
vinegar and water. Soak
only the insert and no
other components.
12
Kohler Co.

Publicidad

Tabla de contenido
loading

Tabla de contenido