5. Technical specifications

Manometer:
Scale:
Graduation of the scales in mm Hg: In steps of 10 mm Hg
Graduation of the scales in kPa:
Display range mm Hg:
Display range kPa:
Pump:
Pressure drop /
pressure reduction:
Cuffs:
Environmental conditions:
Ambient conditions:
Storage and transport conditions:

6. Spare parts and accessories

Art.no. 11219
Art.no. 11220
Art.no. 11221
Art.no. 11222
Art.no. 11223
Art.no. 11224
Art.no. 11225
Art.no. 11227
Art.no. 11228
Art.no. 11229
Art.no.10246

7. Maintenance / accuracy check / calibration / applied standards

The komprimeter and its accessories do not require special maintenance. To
check the accuracy, please remove the tube off the manometer and keep the
manometer in vertical position. If the pointer stops on the zero indicator of the
scale, the device is accurately set. If the pointer is outside of the zero indicator,
please return the device to Riester or to an authorized Riester dealer in your
area. We are happy to provide all necessary information to you upon request.

8. Disposal

Caution!
The used medical devices must be disposed of in accordance with the medi-
cal practices in place, or local regulations for disposal of infectious biological
medical waste.
Batteries and electrical/electronic equipment must be
disposed of in accordance with local regulations, not included with domestic
waste.
16
Ø 55 mm, CuZn chrome plated
Ø 53 mm, aluminium, lacquered and
printed
In steps of 1 kPa
Up to 700 mm Hg
Up to 93 kPa
CuZn chrome-plated, polished 1.4305,
spring steel
Adjustable release valve
Vowalon 121-820 nylon
10°C (50°F) to 40°C (104°F) at a relative
air humidity of 85% (non-condensing)
10°C (50°F) to 40°C (104°F) at a relative
air humidity of 85% (non-condensing)
-20 °C (-4 °F) to 70 °C (158 °F)
at a relative air humidity of 85%
(non-condensing)
Cuff children, 39 x 8 cm 1 tube, black,
Pump
Manometer
Cuff adults, 57 x 9 cm 1 tube, black,
Cuff thigh adults, 96 x 13 cm, black,
Pad adults 46 x 6 cm, 1 tube, latex-free
Pad thigh adults 55 x 10 cm, 1 tube, latex-free,
Cuff cover adults 57 x 9 cm, black,
Adult thigh cuff cover, 96 x 13 cm, black,
Cuff cover children 39 x 8 cm, black,
Pad for child cuff

Publicidad