7. Additional card for AV1 (not supplied as standard):
The AV1 version has a connector (see diagram on page 1) where it is possible to insert an additional card in order to have the outputs for connection
of the electric lock and the sensor light. The lighting time of the sensor light is fixed at 1 minute and 30 seconds. It lights each time the motor begins.
HOLE TO CONNECT THE SPACER
BETWEEN THE ADDITIONAL CIR-
CUIT AND THE CONTROL BOX.
Vac/dc
Some points on the electrical control panel have a dangerously high voltage. Therefore the installation, the ope-
ning and the programming of the panel must be carried out by qualified personnel only.
Use equipment that ensures the omnipolar disconnection of the system's power supply. This can be a switch
(directly connected to the power terminals) with a minimum distance of the contacts of 3 mm in each pole, or a
device integrated into the power network.
It is advised that you control the absorption of all the devices connected to the control panel's outputs, such as
pilot lights, photoelectric cells, safety devices etc. in order to enter within the limits shown in the technical details
table. We cannot guarantee correct working of the product if these limits are not observed.
In order to maximize the capacity of the central unit, it is necessary to pay attention to the antenna: it must not be
directed towards walls and/or metallic screens. The terminals of the antenna's screened cable must be tightly clo-
sed.
The tuned antenna is necessary in order to be able to obtain the maximum performance from the system. Contra-
rily the range could be reduced to a few metres.
The manufacturer accepts no responsibility for damage caused by ignoring these warnings.
Power voltage
Power accessories
Motor output
Working temperature
Working time
Automatic reclosure time
Receiver frequency
Available reception
Impedance of antenna
Number of codes
Capacity
GUARANTEE - The producer's guarantee is valid in compliance with the law, from the date stamped on the product and is limited to repair work and
free replacement of pieces recognised as faulty for problems with the quality and/or materials due to bad workmanship. The guarantee does not cover
damage caused by foreign elements, maintenance errors, overloading, natural wear, incorrect choice, faults in the assembly, or other causes not con-
trollable by the manufacturer. Products which have been tampered with are not covered by the guarantee and will not be repaired.
The information stated here is purely indicative. No responsibility will be accepted for capacity reduction or malfunctions caused by environmental inter-
ferences. The reasonability that lies with the Producer for damage that derives from accidents of any kind caused by our faulty products is exclusively
that which is stated in the Italian law.
6-1622081
REV.11
27/07/2012
1
2
3
4
LC
ELS
WARNING:
Technical details
230 Vac +10% -15% 50Hz
24 Vac 1,5W MAX
230Vac 500W MAX
-10 +60 ° C
from 1 to 180 s
from 4 to 120 s
433.92 MHz
30.875 MHz
quartz
Fixed code
Fixed code
Rolling Code
50 W
4096 (receipt of fixed code)
18 billion billion (Rolling Code receipt)
50-150 in unlimited
50-150 in unlimited
space
space
ITA
ENG
CONNECTOR TO INSTALL TO THE
AV1 CENTRAL COMPUTER
TERMINALS 1 & 2: Output for sensor light. Timed for 90 SEC.
TERMINALS 3 & 4: Output for electric lock. Timed for 3 SEC.
CLEAN CONTACTS WITHOUT VOLTAGE
Max load 220 V - 5 A
Vac/dc
40.665 MHz
quartz
Rolling Code
* Device not for UE market.
50-150 in unlimited
space
FRA
ESP
DEU
POR
306 MHz (*)
extra-reactive
Fixed code
50-150 in unlimited
space