Generator Cord Sets
The generator includes two, 25 ft. (7.6 m) generator
cord sets. Each cord set is designed to provide 120
Volt, 15 Amps through three outlets. Plug one cord set
into each 120 Volt, 20 Amp duplex receptacle.
NOTICE DO NOT use both cord sets on the same
duplex receptacle.
The maximum load on each outlet is 15 Amps. The
maximum total load on each cord set is 15 Amps.
NOTICE Follow all safety precautions on cord tag when
connecting any extension cord or device to the generator.
STATSTATION™
The control panel has a built in LCD display to monitor
the following features:
• Load Monitor (Total Generator Load)
• Hour Meter (Total Generator Hours)
• Maintenance Reminder (Engine Maintenance)
When the generator is first started, the following title
screen will display for three seconds.
Load Monitor
The load monitor measures the output wattage
(generator load) of all the generator receptacles and
will display "TOTAL PWR" (total power) along with
percentage of total generator load.
If the output wattage of "TOTAL PWR" is between 90%
and 100%, the text will flash. If it reaches 101%, the
LCD display will change to "OVERLOAD REMOVE
LOAD".
NOTICE Failure to remove load from generator
could cause circuit breaker(s) to open and/or possible
damage to generator.
16
Hour Meter
The LCD on the control panel also has a built in hour
meter that displays and records how many hours your
generator has run (up to 9,999.9).
Maintenance Reminder
The LCD on the control panel also has a built in
maintenance reminder to alert you to check oil, change
air filter, change oil, and change spark plug. The LCD
will display the following screens for the different
maintenance intervals:
• "CHECK OIL 8HRS HOLD TO RESET" after
every 8 hours of operation.
• "AIR CLEANER 25HRS HOLD TO RESET" after
every 25 hours of operation.
• "OIL CHANGE 50HRS HOLD TO RESET" after
every 50 hours of operation.
• "SPARK PLG 100HRS HOLD TO RESET" after
every 100 hours of operation.
The different maintenance interval hours will count
down to zero hours when the generator is running.
When a maintenance interval reaches zero hours
the LCD screen will flash the maintenance to be
performed. Once maintenance has been performed,
you must push and hold the display button on the
control panel for a minimum of 3 seconds to reset the
timer for each maintenance interval.