INTRODUCTION
The Thermador Professional
units available in a number of configurations.
Model P304 is equipped with four sealed gas surface
burners and a 30-inch gas convection oven with broil
capability. Models P364GE, PG364GL, and P366 fea-
ture a gas cooking surface with four sealed gas surface
burners with either an electric griddle or gas grill or six
sealed gas surface burners plus a 36-inch gas convec-
tion oven with broil capability.
GAS type verification
Verify the type of gas supplied to the location. Ensure
that the appliance is connected to the type of gas for
which it is certified. Ranges are certified for use with only
natural gas or propane (LP) gas. Make certain the range
matches the gas type available; these ranges are not
convertible between gas
WARNING
To avoid possible burn or fire hazard, a
backguard designed specifically for this range
must be installed whenever the range is used.
Refer to the Backguard Installation instructions on page
15, for the correct backguard models that are designed
for this range. After selecting the correct backguard, the
range must be installed properly, using the minimum
clearances to combustible surfaces specified in the
Cabinet Preparation instructions on pages 5 and 6.
Important
•
A backguard must be utilized when there is less than
a 12" horizontal clearance between combustible mate-
rials and the back edge of the range. The Thermador
Low Back backguard must be ordered separately and
installed at the rear of the range. For island installations
and other installations with more than 12" clearance,
an optional stainless steel Island Trim is available to
cover the backguard mounting flanges.
•
Verify that the appliance is correct for the type of gas
being provided. Refer to Step 5 on Page 13 before
proceeding with the installation.
Gas Supply:
Natural Gas – 6 inch water column. (14.9 mb) min.,
8 inch (20 mb) nominal
Propane Gas – 11 inch water column. (27.4 mb),
14 inch (34.9 mb) maximum
Electric Power Supply:
30" Model:
P304 - 120 VAC, 60 Hz., 1Ph., 10 Amp circuit.
Important Installation Information
Ranges are free standing
®
types.
36" Models:
P366 – 120 VAC, 60 Hz., 1Ph., 10 Amp circuit.
P364GL – 120 VAC, 60 Hz., 1Ph., 10 Amp circuit.
P364GE (with electric griddle) – 120 VAC, 60 Hz., 1Ph., 20
Amp circuit.
CAUTION
When connecting the unit to propane gas, make
certain the propane gas tank is equipped with its
own high-pressure regulator in addition to the
pressure regulator supplied with the range. The
maximum gas pressure to this appliance must
not exceed 14.0 inches water column (34.9 mb)
from the propane gas tank to the pressure
regulator.
CAUTION
This unit is designed as a cooking appliance.
Based on safety considerations, never use it for
warming or heating a room
This appliance has been tested in accordance with ANSI
Z21.1, Standard for Household Cooking Appliances
(USA) and in accordance with CAN 1.1-M81 Domestic
Gas Ranges (Canadian).
It is strongly recommended that this appliance be in-
stalled in conjunction with a suitable overhead vent
hood. (See Step 1 for Ventilation Requirements.) Due to
the high heat capability of this unit, particular attention
should be paid to the hood and duct work installation to
assure it meets local building codes.
CAUTION
To eliminate risk of burns or fire caused by
reaching over heated surface units, cabinet
storage located above the surface units should
be avoided.
Check local building codes for the proper method of
appliance installation. Local codes vary. Installation,
electrical connections and grounding must comply with
all applicable codes. In the absence of local codes the
appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1/FNPA 54 current
issue and National Electrical Code ANSI/NFPA 70-
current issue. In Canada, installation must be in accor-
dance with the CAN 1-B149.1 and .2 – Installation
Codes for Gas Burning Appliances and/or local codes.
This appliance is equipped with an intermittent/inter-
rupted ignition device that cycles the left front surface
burner on and off when in the ExtraLow
2
.