i-Monitor Display Mode 1
This mode displays the total operating hours of the generator. When
the generator is running, the total operating time accumulates. If the
total operating time is less than one hour, the numeric display will be
''0.'' When the operating time is one hour or greater, the display will
be ''1'' or ''2'' and so on. Base the generator's maintenance schedule
on the accumulated time displayed.
i-Monitor Display Mode 2
This mode displays an approximate generator output on the display
screen. The output is expressed in VA (volt amperes). The output value
is not an exact measurement and should be regarded as a reference
only. Power output will not display until a load is connected to the
generator.
i-Monitor Display Mode 3
When the i-Monitor is in this mode, the engine's speed, expressed in
revolutions-per-minute (RPM), is displayed.
Total Operating Hours
Power Output
Engine RPM
19