OPERATION
Controls
The hood is operated using the joystick control located
hood. Fig. 1.
LIGHTS
BLOWER.SPEED.
(-).OFF
DISPLAY
BLOWER
SPEED
(+).ON
DELAY.OFF
FIG.. 1
CENTER
LINE
FIG.. 2
- 4 -
on the front edge of the
Lights - Push the joystick upward to turn
the lights on to low. Push again for high
and again to turn the lights off.
Blower.Speed.(-).Off - With the blower
motor on. Push the joystick to the left to
reduce the blower speed to the desired
level. Pushing the joystick past the lowest
speed will turn the blower off. If the filter
alarm is active, pressing and holding the
joystick to the left for 2 seconds resets the
filter alarm.
Blower.Speed.(+).On - Push the joystick
to the right to turn the blower on. Continue
to push the joystick to the right to increase
blower speed.
Blower/Lights,.On/Off - Press the joystick
to turn on the blower to its last stored
speed. Press and hold the joystick in for 2
seconds and it will turn off the blower and
the lights (the blower speed will be stored).
Delay.Off - Push the joystick downward
to activate the 10 minute timer function.
The blower speed on the display will start
blinking to indicate this function. After 10
minutes of operation, the motor will turn off.
If you change the speed while the timer is
running, the function is not deactivated. To
deactivate the function, press the joystick
downward or to the left to turn blower off.
Display - Shows the current blower speed.
When the blower is off it will indicate the
filter alarm: after 30 hours the Center.Line
of the display will stay on. (See Fig. 2). After
120 hours the center line will flash.
Filter Alarm (Fig. 2.)
After 30 hours of blower operation, the
Center.Line of the Display will stay on
for 30 seconds each time the blower is
turned off.
After 120 hours of blower operation,
the center line of the display will flash
for 30 seconds each time the blower is
turned off.
To reset the alarm, press and hold the
joystick to the left: Blower.Speed.(-).Off.
Note: The hour count will not be lost if
there is a power failure.