Descargar Imprimir esta página

Technical Specifications; Data Sheet; Tab. 6: Technical Data Of The Safe Bus Node Ue4215 - SICK UE4215 Manual De Instrucciones

Ocultar thumbs Ver también para UE4215:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Operating Instructions
UE4215
9

Technical specifications

Tab. 6: Technical data of the
safe bus node UE4215
8010654/TF83/2010-07-20
Subject to change without notice
Technical specifications
9.1

Data sheet

General system data
1)
Safety Integrity Level
1)
SIL claim limit
Category
1)
Performance Level
PFHd (mean probability of a
dangerous failure per hour)
T
(mission time)
M
Protection class
Enclosure rating
Power-up delay after the
application of all power
supplies
Weight
AS3interface
Operating voltage (DC)
Power consumption
AS7interface profile
AS7interface master version
Data bits IN
Input channel I1
Input channel I2
Data bits OUT
Maximum number UE4215
per master
AS7interface certification
AUX PWR
Operating voltage U
V
2)
Residual ripple
1)
For detailed information on the exact design of your machine/system, please contact your local SICK
representative.
2
Within the limits of U
.
V
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Minimum
Typical
SIL3 (IEC 61 508)
SILCL3 (EN 62 061)
Category 4 (EN ISO 13 84971)
PL e (EN ISO 13 84971)
–9
9 × 10
20 years (EN ISO 13 849)
III (EN 61 140)
IP 67 (EN 60 529)
85 g
26.5 V
20 mA
S-0.B.E
2.1
AS7interface Safety at Work code sequence on D0, D1
AS7interface Safety at Work code sequence on D2, D3
Not used
Certificate No. 53 001, test laboratory STZ Leipzig
16.8 V
24 V
GB
Chapter 9
Maximum
200 ms
31,6 V
60 mA
31
28.8 V
5 V
ss
101