2SHUDWLQJ ,QVWUXFWLRQV
3.2.2 Adjustment of Control Parameters in the Second Operating Phase
Press the UP and DOWN keys (11/10) simultaneously for at least 4 seconds to access a list of control
parameters (beginning with P1). Pressing the UP key scans the list upwards and the DOWN key
downwards.
The value of the corresponding parameter is displayed when the SET key (9) is pressed. Press the UP
or DOWN key in addition in order to set the value. Release all the keys to store the new value. The
original settings are restored if no key is pressed for more than 60 seconds.
Parameters
P1
Lowering set point
P2
Waiting time until lowered
P11
Elapsed time indicator,
"Units digit"
P12
Elapsed time indicator,
"Thousands digit"
P13
Number of releases,
"Units digit"
P14
Number of releases
"Thousands digit"
P19
Keyboard disabled
(Set point adjustment disabled
P19 Keyboard Disabling
Keyboard disabling enables the operating keys to be locked. In the locked position it is not possible to
change the set value with the keys. If an attempt is made to adjust the set value despite keyboard
disabling, the display shows the message "-".
Functional specification
Setting range
not adjustable
not adjustable
0: Not disabled
1: Disabled
- 11 -
Default set-
ting
-
-
0