ProDuct sPecifications

Name and Item Number
Women's Wrist Blood Pressure Monitor, 04-825-001
Display System
Digital display/LCD
Measuring Method
Oscillometric Method
Automatic Air Inflation and Measurement
Power Source
2 X 1.5V
Measuring Range
Pressure: 0 to 300 mmHg
Pulse: 40-180 beats/minute
Accuracy
Pressure: ±3 mmHg; Pulse: ±5% of reading
Diastolic Range
40-199 mmHg
Systolic Range
60-260 mmHg
Pressurization
Automatic pressurization by pump
Deflation
Automatic pressure-release valve
Memory
Built-in memory enabling display of up
to 60 measurements
Automatic Power-Off
Approximately 1 minute after last button operation
Battery Life
Approximately 120 times
Operation Environment
Temperature 41°F – 104°F (5°C – 40°C)
Humidity ≤90% RH max
Storage Environment
Temperature -4°F – 131°F (-20°C – 55°C)
Humidity ≤90% RH max
Weight
4.3-oz. (without batteries)
Dimensions
3⅝" x 2⅞" x 1⅛"
Wrist Circumference Range
Suitable for 5½" – 7⅝" (14 cm – 19.5 cm)
Accessories
Storage case, Instruction Guidebook, 2
AAA alkaline batteries, Quick Start Guide
Specifications are subject
to change without notice.
04-825-001 IM_13Feb2015.indd 24-25
Size AAA batteries
24
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause
undesired operation.
ELECTROMAGNETIC COMPATIBILITY INFORMATION
Table 1
For all ME EQUIPMENT and ME SYSTEMS
Guidance and manufacture's declaration - electromagnetic emission
The 04-825-001 is intended for use in the electromagnetic environment specified
below. The customer or the user of the 04-825-001 should assure that it is used in
such an environment
Emissions test
Compliance
RF emissions
Group 1
CISPR 11
RF emissions
Class B
CISPR 11
Harmonic emissions
IEC 61000-3-2
Not Applicable
Voltage fluctuations/ flicker
emissions IEC 61000-3-3
Electromagnetic
environment guidance
The 04-825-001 uses RF
energy only for its internal
function. Therefore, its RF
emissions are very low
and are not likely to cause
any interference in nearby
electronic equipment.
The 04-825-001 is
suitable for use in all
establishments other
than domestic and those
directly connected to
the public low-voltage
power supply network that
supplies buildings used for
domestic purposes.