Chapter 1. Controls
formula. The formula resumes where it was interrupted or at the beginning of the previous
bath step, depending on the operation in progress when the emergency stop button was
pressed.
Master power switch (
switch off (
) while a formula is running, the immediate result is similar to pressing the
m
emergency stop button: the machine stops and the drain opens. Unlike the emergency stop
button, resumed formulas start at the beginning of the step in which power was lost, but
chemicals are not injected in the resumed step.
Operator signal cancel button (
buzzer and turn off the operator signal light (see below), or to allow injection of a chemical
programmed to require a signal before injection.
Operator signal light—indicates that the machine has encountered an error or that the operator
must perform some action, such as pressing the start button or unloading the machine. The
operator signal circuit includes a buzzer behind the control panel, and may include an optional
beacon light mounted separately from the control panel.
Liquid crystal graphic display—displays information and help about the machine. The
information on the display changes according to the status of the machine and the function
selected by the operator.
Keypad—allows the operator to communicate with the machine control system. The keypad is
divided into three areas: alphanumeric buttons, general buttons, and function-specific buttons.
Each button may perform more than one function, based on the current machine status. Some
buttons are also used in combinations for additional functions.
Start button (
)—starts the selected wash formula. The start button energizes the 3-wire circuit
1
to allow the machine to operate.
Stop button (
)—stops machine operation. Like the emergency stop button, the stop button
0
disables the 3-wire circuit; however, the stop button doesn't require you to manually reset it
after use.
Run/Program keyswitch (
configuration and wash formulas, among other actions. In the normal Run position, formulas
and configuration are protected and formulas can be run.
What are the Loading Controls?
1.1.4.
Loading controls allow you to open and close the door, as well as jog the cylinder; used primarily
when loading and unloading a tilting machine.
Door open/close switch (
To open the door, turn the switch to the right (
Turn the switch to the left (
controls when the door is in the correct position. The hydraulic pump which powers the door
shuts off automatically when the door is fully open or fully closed.
Door open button (
door open button while the machine is operating removes power from the 3-wire circuit,
stopping the machine. When the machine is idle, this button must be pressed to perform any
other loading or unloading function. This requirement helps ensure that you have both hands
safely on the control panel of the machine if the basket might turn under power while the door
is open.
WARNING 2 : Fall, Entangle, and Strike Hazards—Contact with the turning cylinder can
crush your limbs. The cylinder will repel any object you try to stop it with, possibly causing the
object to strike or stab you. The turning cylinder is normally isolated by the locked cylinder door.
PELLERIN MILNOR CORPORATION
/
)—removes power from the control system. If you turn the master
m
M
)—cancels the operator signal. Press this button to silence the
A
/
)—in the Program position, allows changes to machine
R
P
/
)—controls the automatic door system when the machine is idle.
d
D
) and press the door open button to close the door. Release the
d
)—enables other loading controls when the machine is idle. Pressing the
l
10
) while pressing the door open button (
D
).
l