Chapter 2. Normal Machine Operation
How do I Load a Non-tilting Machine?
2.1.3.
Display or Action
How do I Select a Formula?
2.1.4.
The Mark VI controller can operate in either local or Mildata mode. In local mode, the machine
does not communicate with any other devices and runs formulas contained in local controller
memory. In Mildata mode the machine downloads and runs formulas from the Mildata computer,
and frequently updates the display on the Mildata computer.
Figure 9: Selecting a Local or Remote Formula
.
Selecting a Local Formula
2.1.4.1.
Mildata network is not available, you can choose from any of the wash formulas stored in local
memory on the machine. Use the Select Local Formula screen
formula for the goods in the machine.
PELLERIN MILNOR CORPORATION
Explanation
Open the outer door.
d+l
Open the inner door of the first pocket to load.
Select the formula (07, for example). Details about selecting a
0 7
formula are described in
Formula?".
Toggle column for formula selection if necessary.
k
Move to the next or previous displayed formula in the current
&/^
column.
Confirm the selected formula.
u
Close the door.
D+l
Select Program Displays
—If the machine is not part of a Mildata network, or if the
Section 2.1.4 "How do I Select a
A.
B.
(Figure
14
Legend
Local (Mildata not present
or enabled)
Remote (Mildata enabled)
10) to choose the correct