Principle Of Operation; Application Area; Adjustment; Packaging, Transport And Storage - SICK LFC Manual De Instrucciones

Ocultar thumbs Ver también para LFC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1
2
12...35V
3
PNP 250mA
4
IP66/67/69, TYPE 6P
MWP 25bar (2500kPa)
5
PEEK, FKM, 316L
6
2019
www.sick.com
D-79183 Waldkirch,
Made in Germany
Abb. 12: Layout of the type label (example)
1
Product name
2
Serial number
3
Voltage supply and signal output
4
Protection rating
5
Permissible process pressure
6
Material wetted parts
7
QR code for device documentation
8
Fabrication year
9
Approvals
Documents and software
Further information can be found on our home-
page.
There you will find the documentation and
further information about the device.
3.2

Principle of operation

Application area

The LFC is a capacitive point level sensor for
point level detection
It is designed for industrial use in all areas of
process technology and can be used in water-
based liquids.
Typical applications are overfill and dry run pro-
tection. With a the small sensor unit, LFC can be
also mounted e.g. in thin pipelines. The sensor
allows use in vessels, tanks and pipes. Thanks
to its simple and robust measuring system,
LFC is virtually unaffected by the chemical and
physical properties of the medium.
It functions even under difficult conditions such
as turbulence, air bubbles, buildup, strong
external vibration or changing products.
If a malfunction is detected or in case of voltage
supply, the electronics takes on a defined swit-
ching status, i.e. the output is open (safe state).
LFC • Transistor (PNP)
LFC
s/n 1234567
9
1W
8
7
Functional principle
An alternating electric field is generated at the
tip of the measuring electrode. If the sensor is
covered with medium, the capacitance of the
sensor changes. This change is detected by
the electronics and converted into a switching
command.
Buildup is ignored to a certain degree and
therefore has no influence on the measurement.
3.3

Adjustment

The switching status of LFC can be checked
from outside (signal lamp).
3.4
Packaging, transport and
storage
Packaging
Your instrument was protected by packaging
during transport. Its capacity to handle normal
loads during transport is assured by a test
based on ISO 4180.
The packaging consists of environment-friendly,
recyclable cardboard. For special versions,
PE foam or PE foil is also used. Dispose of the
packaging material via specialised recycling
companies.
Transport
Transport must be carried out in due conside-
ration of the notes on the transport packaging.
Nonobservance of these instructions can cause
damage to the device.
Transport inspection
The delivery must be checked for completeness
and possible transit damage immediately at re-
ceipt. Ascertained transit damage or concealed
defects must be appropriately dealt with.
Storage
Up to the time of installation, the packages
must be left closed and stored according to the
orientation and storage markings on the outside.
Unless otherwise indicated, the packages must
be stored only under the following conditions:
Not in the open
Dry and dust free
Not exposed to corrosive media
Protected against solar radiation
Avoiding mechanical shock and vibration
3 Product description
19