Functioning Of The Programmable Input; Alignment; Configuration; Setting The Switching Output Via The Teach-In Quick Access Button (-/Q1) (+/Q2) (Set/Q3) - SICK PowerProx Small Teach-in WTT190L-K1 Serie Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
3.4

Functioning of the programmable input

3.5

Alignment

4

Configuration

4.1
Setting the switching output via the teach-in quick access button (-/Q1) (+/Q2)
(Set/Q3)
8020034.ZX33 | SICK
Subject to change without notice
PNP mode
Deactivated
Active
NPN mode
Deactivated
Active
The programmable input must be active for the durations specified below (e.g., U
> 10.0 V in PNP mode ) in order to set the corresponding functions. For a description of
the available functions and how to select them via the menu, see
outputs and other sensor configurations via the menu", page 8
Function
Laser shutdown
External teach-in Q1
External teach-in Q2
Align the sensor with the object. Select the position so that the red emitted light beam
hits the center of the object. You must ensure that the optical opening (front screen) of
the sensor is completely clear [F]. We recommend making the adjustments using an
object with a low remission.
Figure: E
Perform configuration:
The sensing range is adjusted by pressing the teach-in quick access button for > 1 s.
NOTE
The teach-in quick access button (Set/Q3) is only active if the OUT option has previously
been selected in the MF menu item. See section
Value
Notes
< 5.0 V
Also deactivated when not connected
> 10.0 V
Max. applied voltage not higher than
UV
> 10.0 V
Max. applied voltage not higher than
UV
< 4.0 V
Also active when not connected
Minimum duration
4 ms
4 ms
1 s
chapter 4.2
COMMISSIONING
„Setting the switching
Maximum duration
-
1 s
2 s
for more information