The FGS safety light curtain comprises two components, the
sender and the receiver (Fig.).
The protective field is the area between the two units.
Intrusion into the protective field triggers a switching
command which shuts down the machine.
3.3
Cascading
The 'Host' and 'Guest' FGS versions can be connected in
series. Host and guest devices of different resolutions (14
and 30 mm) can be used together in conjunction with LCU-P.
In contrast to the host sensor, the guest sensor has no LEDs.
The host sensor and guest sensor cannot be operated as
individual devices.
The following must be observed:
Flexible line length between two cascaded devices:
max. 170 mm, shielded.
Fig. 1 in the appendix shows the necessary components. The
host sensor is preassembled with a quick-disconnect plug
and is ready for cascading. The guest sensor is pre-
assembled with cable and cable receptacle (flexible cable
length 170 mm) and is also ready for connection.