ASG1818WI
Function (indicate if present)
cooling
heating
Item
symbol
Design load
cooling
Pdesignc 4.6
heating/Avera
Pdesignh 3.3
ge
heating/Warm
Pdesignh 3.3
er
heating/Colde
Pdesignh 5
r
Declared capacity (5) for cooling,
at indoor temperature 27(19) °C and
outdoor temperature Tj
Tj = 35 °C
Pdc
Tj = 30 °C
Pdc
Tj = 25 °C
Pdc
Tj = 20 °C
Pdc
Declared capacity (5) for
heating/Average season, at indoor
temperature 20 °C and outdoor
temperature Tj
Tj = – 7 °C
Pdh
Tj = 2 °C
Pdh
Tj = 7 °C
Pdh
Tj = 12 °C
Pdh
Tj = bivalent
Pdh
temperature
If function includes heating: Indicate the heating
season the information relates to. Indicated values
Y
Y
value
unit
Seasonal efficiency
kW
cooling
kW
heating/Average
kW
heating/Warmer
kW
heating/Colder
Declared energy efficiency ratio (5), at
indoor temperature 27(19) °C and outdoor
temperature Tj
4.65
kW
Tj = 35 °C
3.49
kW
Tj = 30 °C
2.19
kW
Tj = 25 °C
1.23
kW
Tj = 20 °C
Declared coefficient of performance 
(5)/Average season, at indoor temperature 20
 °C and outdoor temperature Tj
2.95
kW
Tj = – 7 °C
1.81
kW
Tj = 2 °C
1.25
kW
Tj = 7 °C
1.24
kW
Tj = 12 °C
Tj = bivalent
2.69
kW
temperature
90
should relate to one heating season at a time.
Include at least the heating season ‧Average‧.
Average
(mandatory)
Warmer
(if designated)
Colder
(if designated)
Item
symbol
SEER
SCOP/A
SCOP/W 5.1
SCOP/C
EERd
EERd
EERd
EERd
COPd
COPd
COPd
COPd
COPd
Y
Y
Y
value
unit
6.1
4
3.3
3.15
4.75
7
10.8
2.63
4.13
4.85
5.9
2.45
GB