Troubleshooting - Kohler MasterShower Tower K-74 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. TROUBLESHOOTING

PROBLEM
No flow.
Flow to showerhead only.
Poor flow to sheetflow.
Poor flow to other outlets.
CALL US FOR HELP
Questions? Problems? First review the installation instructions to ensure correct installation. For additional
assistance, call our Customer Service Department for direct help. You may also contact us at our web site listed
below.
A
1017598-2-
PROBABLE CAUSE
A. No water supply.
B. Blocked water filter.
C. Pressure switch malfunction.
D. Strainer screen plugged.
A. No power to unit.
B. Transformer malfunction.
C. Solenoid malfunction.
A. Blocked water filter.
B. Low water pressure.
C. Too many outlets selected.
D. Strainer screen plugged.
A. Blocked water filter.
B. Low water pressure.
C. Strainer screen plugged.
In the U.S.A., call 1-800-4-KOHLER
In Mexico, call 001-877-680-1310
In Canada, call 1-800-964-5590
www.kohler.com
12
PROBABLE SOLUTION
A. Turn on water supply.
B. Clear water filter (not supplied).
C. Contact dealer.
D. Clean or replace strainer screen.
A. Turn on power at circuit breaker.
B. Contact dealer.
C. Contact dealer.
A. Clear water filter (not supplied).
B. Provide 40 p.s.i. (2.8kg/cm@)
minimum static water pressure.
C. Sheetflow performance is optimum
when only sheetflow is selected.
D. Clean or replace strainer screen.
A. Clear water filter (not supplied).
B. Provide 40 p.s.i. (2.8kg/cm@)
minimum static water pressure.
C. Clean or replace strainer screen.
Kohler Co.