Successive presses cause the motor to move (initial position: door closed) as
per the following cycle: open, stop, close, stop, open, etc.
fety Edge
> Alarm
It is essential to have programmed at least one remote control. The
alarm can only be stopped with a memorised remote control.
• Installing and connecting the alarm
Mount the alarm to the receiver with the bolt provided.
Connect the alarm connector.
• Activating/Deactivating the alarm
To activate/deactivate the alarm, simultaneously press the
The alarm emits a beep if it has been activated.
1
2
3
4
Prog
STOP
• Alarm operation
The alarm is triggered for 2 minutes if the door is raised manually.
No movement of the door is possible when the alarm is sounding.
When the alarm sounds, press a button on a remote control memorised in the
receiver to stop it. The alarm can only be stopped with a memorised remote
control.
• Alarm operation test
and
on the receiver simultaneously.
STOP
1
2
3
4
Prog
STOP
10
KeySwitch
Flash
ec
8
9
10
11
12
13
1
and
STOP
1
2
3
4
STOP
• Anti-intrusion function test
[1]. Press button
[2]. Wait until the transmitter switches to sleep mode (instant if base magnet
installed).
[3]. Manually raise the door by pressing on the rubber.
The alarm is triggered.
[4]. Press a button on a remote control memorised in the receiver to stop the
alarm.
• Optional: lower magnet
4.2).

8 - ADVANCED PARAMETER SETTING

8.1 Different operating modes

> 2 operating modes are available:
Sequential (default
mode)
Semi-automatic
> 2 automatic closure options are available for the door:
Closure
time
With automatic closure time delay:
delay
- l the door is closed automatically after the programmed
time delay has elapsed (20 s, by default),
- pressing a button on the remote control interrupts the
movement taking place and the closure time delay (the
door remains open).
Cell locking
After the door is opened, movement in front of the cells (safe
buttons
at 5 seconds).
If there is no movement in front of the cells, the door will
close automatically after the programmed closure time delay
(20 s, by default).
If there is an obstacle in the cells' detection zone, the door
will not close. It will close once the obstacle is removed.
Note: by default, no automatic closure option for the door is activated.
Prog
The installation of photoelectric cells is mandatory in the event that
an automatic closure option is activated.

8.2 Programming operating modes

> Changing the operating mode
Automatic closing mode
> Activating/deactivating automatic closing
to position the garage door in the low position.
Each press on the remote control causes the motor to
move (initial position: door closed) as per the following
cycle: open, stop, close, stop, open, etc.
In semi-automatic mode:
- pressing a button on the remote control during
opening has no effect,
- pressing a button on the remote control during closing
causes it to reopen.
mode to semi-automatic mode.
Indicator lights
Mode activated
M1
M2
M3
Sequential
Semi-automatic
Short press on the T button to activate automatic
closure.
Indicator
Automatic closure option
light
activated
Closure time delay
Cell locking
No option active