Technical Characteristics - GBD SC230 Instrucciones Para La Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

10
UK

1 - TECHNICAL CHARACTERISTICS

Control unit
Type
Power supply
No. of motors
Motor power supply
Flashing light
Warning light
Accessories power supply
Radio receiver
Operating temperature
Working time
2 - TECHNICAL CHARACTERISTICS / FUNCTIONS
• Red warning leds of N.C. contacts (photocell, safety device,closing limit switch,opening limit switch, stop).
• Green warning leds of N.O. contacts (start and ped).
• START and PED buttons on board.
• Safety test run before the opening and closing movement.
• Deceleration during opening and closing controlled by 2 additional magnets to be assembled in the desired
position, at a min. relative distance of at least 500 mm. Deceleration is adjutable with the suitable trimmer
(SLOW).
• Stop and motion inversion for 1s after the intervention of safety devices. At next Start pulse the
motion restarts in the obstacle freeing direction.
• Possibility of reading the motor rpm for the anticrushing function by the suitable sensor, both during
normal operation and in slow motion.
• Pedestrian operation with fixed opening of 10 s.
• SAFETY DEVICE POWER SUPPLY. The connection to this power supply allows the devices TEST before
motion.The safety devices will be connected to this terminal and powered only during the operating cycle.
• 1 input for 8K2 safety device.
• 1 input selectable as 8K2 safety device or STOP 8K2.
Thank you for choosing GIBIDI.
READ CAREFULLY THIS MANUAL BEFORE PROCEEDING WITH THE INST ALLATION.
WARNING: This product has been tested by GI.BI.DI. checking the perfect correspondance of its characteristics to the current directive.
GI.BI.DI. S.r.l. reserves the right to modify the technical data without prior notice, depending on the product development.
DISPOSAL: GI.BI.DI. advises recycling the plastic components and disposing of them at special authorized centres, for electronic
components, protecting the environment from polluting substances.
SC230 / AS05710/115V-AS05711/115V
Electronic control unit for automation of a
sliding gate with 115 Vac motor
115 Vac single-phase 50/60 Hz
1
115 Vac
115 Vac 40W max
24 Vac 3W max
24 Vac 8W max
Plug-in
-20°C +60°C
240 s fixed