Entering Program Mode
1. Unlock and raise top cover.
2. Remove control module cover.
3. Locate the Run/Program Mode switch near
center of computer board inside control module.
Refer to Figure 1.
1
Run/Program Mode Switch
2
Computer Board
Figure 1
4. Flip switch to up position to enter Program
Mode. Display will show temperature of sump.
F232131
Programming
1
2
B152R
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Setup Options
1. With display showing sump temperature, press
Stop (*) key to enter Setup Mode.
2. Use Up or Down (arrow) key to scroll through
setup options. Refer to Table 1 for possible setup
options and description.
Setup Options
"FAr"/"CEL"
Select "FAr": degrees are displayed
in Fahrenheit.
Select "CEL": degrees are
displayed in Celsius.
"noHt"/"HEAt"
Select "noHt": no heat is available
during a cycle regardless of
programmed temperature setting.
Select "HEAt": heat is available as
long as a temperature is
programmed.
"FLSH"/"nFLS"
Select "FLSH": the display will
(VNV models only)
flash "PAY" and a start amount.
Select "nFLS": the display will not
flash "PAY" and a start amount.
"1 Pr"/"16Pr"
Select "1 Pr": all cycles have the
(VC2 models only)
same vend price.
Select "16Pr": each cycle has a
SEPARATE vend price.
"COIn"/"CArd"
Select "COIn": to use standard one
or two denominations drop coin
meter.
Select "CArd": to use card meter.
Amount to Start
Display will read "Strt" then "A
select start amount. (On VC2
models, if "16Pr" is selected, start
amount will be set while editing
individual cycles.)
"Con1"
Display will read "Con1" then
"dEno", select amount for coin 1
denomination.
"Con2"
Display will read "Con2" then
"dEno", select amount for coin 2
denomination.
Table 1
Description
n
t",
7