7601 Soft brush current fold back.
7602 Soft brush current fold back 2.
7603 Soft brush current fold back 3.
7604 Soft brush inhibit.
7605 Brush startup over current detection.
7700 Soft vacuum motor disconnected error Check Vac Motor wiring, connections and carbon brushes.
7701 Soft vacuum current fold back.
7702 Soft vacuum current fold back 2.
7703 Soft vacuum current fold back 3.
7800 Traction motor fault -1.
7801 Traction motor over current error.
7802 Soft traction motor in fold back state.
7803 Motor line voltages instability timeout.
7880 Traction speed input out of range.
7900 Emergency stop error.
7901 Soft belly button activated.
8000 Service mode.
9000 Brushes not fitted.
Code
Code
Code
0003
1800
3104
0100
1802
3105
0204
1B20
3200
0705
1B21
3201
0706
2102
3210
0A01
2103
3211
0B02
2D01
3212
0B0B
3100
3213
1704
3101
3214
1705
3102
3601
1706
3103
3602
PROBLEM
Sidekick pump not operating
Sidekick operating, but not
pumping chemical
Check Brush Motor for excessive amp draw. Check for locked rotor conditions (debris
caught in brushes, gear box locked up, etc.). Repair or Replace as necessary.
Check Brush Motor for excessive amp draw. Check for locked rotor conditions (debris
caught in brushes, gear box locked up, etc.). Repair or Replace as necessary.
Check Brush Motor for excessive amp draw. Check for locked rotor conditions (debris
caught in brushes, gear box locked up, etc.). Repair or Replace as necessary.
Check Brush Motor for excessive amp draw when starting.
Repair or Replace as necessary.
Check Brush Motor for excessive amp draw. Check for locked rotor conditions (debris
caught in brushes, gear box locked up, etc.). Repair or Replace as necessary.
Check Vac Motor for excessive amp draw.
Repair or Replace as necessary.
Check Vac Motor for excessive amp draw.
Repair or Replace as necessary.
Check Vac Motor for excessive amp draw.
Repair or Replace as necessary.
Check Drive Motor wiring, connections.
Check Drive Motor for excessive amp draw. Release Parking Break. Replace as
necessary.
Traction Motor being overloaded or Fold back parameters set too low.
Check Drive Motor wiring, Controller wiring, connections.
Check Drive Motor wiring, Controller wiring, connections.
N/A
N/A
N/A
N/A
Possible Internal TRIO+ Faults
Code Corrective Action
3603 For All Internal TRIO + Diagnostic Codes:
3608
1 - Turn Off Key switch and disconnect batteries.
3609
2 - Wait 1 minute.
360a
3 - Reconnect Batteries and turn On Key switch.
360b
4 - If Diagnostic Code is not cleared, then replace TRIO+.
360c
360d
360e
7501
TROUBLE SHOOTING – SIDEKICK CHEMICAL DISPENSOR
CAUSE
Turned off, water valve is off,
brushes turned off
Improper wiring
Sensor plugged
Vacuum leak at fittings on bottle
cap, Squeeze tube cracked,
chemical bottle empty
SOLUTION
Ensure pump, solution valve, and
brushes are on.
Inspect/repair by qualified technician
Remove sensor and blow air (5psi max)
thru in the opposite direction as the arrow
on the part to clear the obstruction.
Check fittings at bottle cap for leaks.
Replace squeeze tube if cracked. Fill
chemical bottle.