4. Trigger <Up/Down Arrows> to scroll to desired liquid.
5. Trigger <ENTER> to save selection.
Select Pipe Configuration
1. Trigger <Left Arrow> and then <Down Arrow> to select [Pipe Configuration].
2. Trigger <Right Arrow>.
3. Trigger <Up/Down Arrows> to select a configuration that approximates the conditions
4. Trigger <ENTER> to save selection. The [Anomaly Diams] menu will appear.
5. Trigger <Right Arrow> to select "=" sign.
6. Trigger <Up/Down Arrows> to select number of pipe diameters.
7. Trigger <ENTER> to save selection.
8. To return to the top menu level, continue to trigger the <Left Arrow>.
FUH1010 IP65 NEMA 7 Interface Detector Quick Start
Operating Instructions, 06/2014, A5E02428148-AA
①
Colon appears
②
Select new liquid from list.
upstream of your sensor mounting location. (Refer to the definitions below.)
①
Use this menu cell to select the pipe configuration that most accurately represents the
upstream pipe condition.
②
Use this menu cell to enter the number of pipe diameters between the upstream
configuration and the sensor installation.
Commissioning
3.4 Programming the Transmitter