Alarm Letter Codes - Siemens SITRANS FUH1010 IP65 NEMA 7 Compact Guía Rápida

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting

4.2 Alarm Letter Codes

4.2
Alarm Letter Codes
Letter Code
S
E
R
F
A
M
K
I
The display shown below indicates where the Alarm Codes appear on the LCD display
screen.
42
Alarm
Spacing
Transducer spacing may need readjustment.
Empty
Pipe is empty.
Rate
Flow above High setting or below Low setting.
Fault
Three continuous seconds without new data update.
Aeration
Current aeration percentage exceeds the alarm set point.
Memory
Last valid reading for a selected interval during Fault condition.
Makeup
In-Process Makeup occurred.
Interface
Liquid Vs exceeds interface alarm set point.
Alarm Codes
Description
FUH1010 IP65 NEMA 7 Interface Detector Quick Start
Operating Instructions, 06/2014, A5E02428148-AA

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

7me3601-1

Tabla de contenido