4.1. TERMINAL BOARD M1

4.1.1 O
A
PEN
Terminals "OPEN A - COM 2". Normally open contact. Connect, to these terminals, any device (push-button, key selector,
etc.) that commands total opening of the gate. The operation of this contact is defined by parameter D.
•An OPEN A pulse, total opening, always has priority on OPEN B, partial opening.
•To install several pulse generators, connect the contacts in parallel.
4.1.2 O
B
PEN
Terminals "OPEN B - COM 2". Normally open contact. Connect, to these terminals, any device (push-button, key se-
lector, etc.) that must command partial opening of the leaf. Partial opening is non-adjustable and equals 30% of the
memory-stored total opening.
• An OPEN A pulse, total opening, always has priority on OPEN B, partial opening.
• To install several pulse generators, connect the contacts in parallel.
4.1.3 STOP
COMMAND
Terminals "STOP - COM 2". Normally closed contact. Connect, to these terminals, any safety device (push-button, key
selector, etc.) that must stop gate movement. The status of this input is signalled by LED DL2 "STOP".
• If no STOP devices are connected, jumper connect the input.
• To install several STOP devices, connect the normally closed contacts in series.
4.1.4 C
LOSING SAFETY DEVICES
Terminals "FSW CL - COM 2". Normally closed contact. Connect, to these terminals, any safety device (photocells,
safety edge, etc.) that must control gate closing motion by reversing gate movement up to the maximum memory-
stored opening. The status of this input is signalled by LED DL3 "FSW-CL".
• If no closing safety devices are connected to the closing motion, jumper connect the input.
• To install several safety devices on the closing motion, connect the normally closed contacts in series.
4.1.5 O
PENING SAFETY DEVICES
Terminals "FSW OP - COM 2". Normally closed contact. Connect, to these terminals, any safety device (photocells, safety
edge, etc.) that must control gate opening motion by stopping its movement. When the safety device is released, motion
will resume normally, executing the memory-stored cycle. The status of this input is signalled by LED DL4 "FSW-OP".
• If no safety devices are connected to the opening motion, jumper connect the input:
• To install several safety devices on the opening motion, connect the normally closed contacts in series.

4.2 M2 TERMINAL BOARD

4.2.1 E
NCODER
Terminals "SIG. - -ENC - +ENC". Use the encoder supplied with the control unit. On the "SIG" terminal: connect the
return signal from encoder terminal "S"; connect encoder terminal "V-" to the "-ENC" terminal; connect encoder
terminal "V+" to terminal "+ENC".
• The encoder must be used for operation of the control unit
• For encoder operation, observe the connection between terminals as described above.
4.2.2 C
LOSING LIMIT SWITCH
Terminals "COMF - FCC". Normally closed contact. Connect the closing limit-switch, if any, to these terminals. The switch
operates by stopping the gate closing motion. The status of this input is signalled by LED DL5 "FCC".
•If no closing limit-switch is used, the input must be jumper connected.
4.2.3 O
PENING LIMIT SWITCH
Terminals "COMF - FCA". Normally closed contact. Connect the opening limit-switch, if any, to these terminals. The
switch operates by stopping the gate opening motion. The status of this input is signalled by LED DL6 "FCA".
• If no opening limit-switch is used, the input must be jumper connected.