Technical specifications
4. Technical specifications
4.1. Chargers
Functional
Standard and charging mode
User interface
Status indication
Consumption measurement
Access control
Static power control
Dynamic power control
Charging scheduling
No. of EVs that can be charged simultaneously
Electrical
Frequency
Maximum current (per phase)
Power supply
Voltage
Maximum output power
No. of connectors
Connector type
Safety
Power cut
Protection against electric shock
Relay fault detection in case of welded contacts
Detection of ground connection presence
Detection of correct supply connection
Direct current leak detection
Communications
Bluetooth
Wi-Fi
Ethernet
Modem
Mechanical
Material
Anchor type
Height (mm)
Width (mm)
Depth (mm)
Weight (including 3 m/5 m/7 m charging cable)
IP rating
IK rating
Connector support (on unit with integrated cable)
Cable length (on unit with integrated cable)
Power terminal block
Maximum power cable gage
Color
Environmental
Suitable for outdoor use
Operating temperature
Storage temperature
ABV2011IQM01_ - Installation and Operation Manual
IEC 61851-1 Ed 3.0 Mode 3
Direct metering with shunt
Individually for each charger
For each charger, with a setpoint that will vary with the measurement of the Ingeteam CURVE device in real time
Integrated charging cable Type 1
Integrated charging cable Type 2
Flame-retardant PC/ASA (V0). Suitable for outdoor use
Ground with the STAND accessory
3.15 kg/3.75 kg/4.35 kg
Accessible from the exterior (no need to open the unit during installation)
NEO
Ingeteam NEO app
Multicolor LED
Free
Proximity
Manual
Yes
1
50-60 Hz
32 A
Single-phase (P+N+E)
AC 230 V
7.4 kW
1
Socket Type 2
Latching relay 80 A
Class II
Yes
Yes
Yes
No
BLE 4.2
No
No
No
Wall
365
220
105
IP54
IK10
Integrated in the unit
3 meters
5 meters
7 meters
10 mm
2
White
Red
Yes
-25 to 40°C
-25 to 60 °C
Ingeteam
EN
ES
FR
IT