Power cord conductor shorting to ground.
Check the wiring.
Motor shorted.
Renew the motor.
Rotation control pedal fails to return to the central position
Control spring broken.
Renew the spring.
Bead breaker pedal and table top pedal do not return to home position
Control spring broken.
Renew the spring.
No oil in lubricator.
Top up lubricator with SAE20 non-detergent oil.
Air leak from bead breaker cock.
Renew the cock.
Renew bead breaker cylinder.
Air leak from the table top cock.
Renew table top cylinder.
Renew swivel connector.
Bead breaker cylinder lacks force, fails to break beads and leaks air
Silencer plugged.
Renew silencer.
Cylinder seals worn.
Renew seals.
Renew bead breaker cylinder.
Bead breaker cylinder leaks air around the rod
Air seal worn.
Renew seals.
Renew bead breaker cylinder.
Inverter faulty.
Replace inverter (microswitch for 2V).
Belt broken.
Renew belt.
Gear unit broken.
Renew gear unit.
Gear unit noisy. The table top makes 1/3 of a revolution and then stops
Gear unit seizing.
Renew gear unit.
Table top does not clamp rim.
Renew table top cylinder.
Clamp grippers are worn.
Renew clamp grippers.
TROUBLE SHOOTING
Table top will not rotate.
Air leak inside the machine
Table top will not rotate in either direction
Table top fails to clamp wheels
34