ADJUSTING THE WELL "FULLY RAISED" MICROSWITCH
Important
This adjustment must
be made with the well
completely raised.
To carry out this operation,
proceed as follows.
1 - Undo the screws (C)
and remove the control
panel (D).
2 - Undo the screws (E) to remove the lid (F).
3 - Undo the screw (G).
4 - Position the microswitch (H) so that it is
touching the bracket (L).
5 - Tighten the screw (G).
6 - Fit the lid (F) and secure it with the screw (E).
7 - Replace the control panel (D) on completion of
the operation.
8 - Raise and lower the well to check that the set-
ting is correct.
IT
GB
DE
ADJUSTING THE LID COUNTER-BALANCING
To carry out this operation, proceed as follows.
1 - Fit the spanner (A) onto the hexagon (B).
FR
2 - Keep a firm grip on the spanner (A) and undo
the locking screws (C).
ES
3 - Turn the spanner (A) clockwise to load the
spring or anti-clockwise to release it.
4 - Once the correct balance is obtained, screw in
the screws (C) without tightening them fully.
5 - Use the spanner (A) to turn the shaft until it is
located in one of the seats provided.
6 - Fully tighten the screws (C).
English
D
C
E
C
C
- 24 -
D
C
F
L
H
G
A
A
B
B
IDM-39616701000.tif
IDM-39616201500.tif
IDM-39616301600.tif
IDM-39615401800.tif