PROBLEMS WITH MAKING INFLATED MATERIAL CONTINUED
PROBLEM
The material advances and
fills with air, but the material
does not seal properly.
The inflated material leaks air.
PAGE 9 OF 30
TROUBLESHOOTING CONTINUED
CAUSES
Material roll improperly loaded.
Faulty edge seal.
Faulty material.
Seal power out of adjustment.
Electrical or mechanical failure.
Material roll improperly loaded.
Faulty edge seal.
The operator is pulling the inflated
material directly out of the system
before the inflated material can cool.
Faulty material.
Seal power out of adjustment.
Electrical or mechanical failure.
RECOMMENDATIONS
Reload material roll – see Loading the
Material Load on page 4.
Check condition of edge seal on the material.
Check condition of edge seal and verify that
it is fully seated.
Replace as required – see Replacing the
Edge Seal.
Load new material – see Loading the Material
Roll on page 4.
Return material roll – contact Uline Customer
Service.
Remove, re-install and calibrate the edge
seal – see Replacing the Edge Seal on page 7.
Contact Uline Customer Service.
Reload material – see Loading the Material
Roll on page 4.
Check condition of edge seal on the material.
Check condition of edge seal and verify that
it is fully seated.
Replace as required – see Replacing the
Edge Seal on page 7.
Do not attempt to pull inflated material from
machine.
Load new material – see Loading the Material
Roll on page 4.
Return material roll – contact Uline Customer
Service.
Remove, re-install and calibrate the edge
seal – see Replacing the Edge Seal on page 7.
Contact Uline Customer Service.
0521 IH-7259