Maintaining the Everest 600 Printer
4. Locate the swab handle found in the Everest Cleaning Kit. Remove the
sponge swab from the swab handle if necessary.
Sponge
Swab
Swab
Handle
Tip: One end of the handle has a slot with a notch in it approximately ¼
inches from the end. This is the end that goes into the printer.
5. Clean the sensors.
a. Position the slotted end of the swab handle by the sensor. Refer to
page 27 for the sensors' location.
b. Position the can of compressed air's nozzle in the unnotched end of
the handle.
c. Blow compressed air in to the end of the handle for one to two
seconds.
d. Repeat two to three times.
e. Repeat for each of the three sensors.
2001474_B
6. Prepare the Printer for use.
The printer is ready for use.
Notch
For more information visit
rimage.com/support
a. Replace the print ribbon carrier.
b. Replace the retransfer ribbon carrier.
c. Close the latches.
d. Close the cover.